Services Areas We Cover About Us Roofing Guides Contact Call: 085 224 5900 Get Free Quote

Where a chimney stack passes through a pitched roof, there is a joint between masonry and slates or tiles that has to stay watertight through decades of rain, wind and movement. That joint is covered by flashings, usually lead on Irish houses, though older or cheaper work sometimes relies on a mortar fillet. When the damp appears, the flashing is the first suspect.

How a chimney is weathered

A properly flashed chimney on a pitched roof has several parts:

  • Front apron flashing on the downslope side, dressed over the slates or tiles and tucked into a mortar joint in the stack.
  • Step flashings up each side, cut in steps to follow the brick or block courses, often with separate soakers under each slate.
  • A back gutter on the upslope side, a small lead gutter that collects water running down the roof and sends it around the stack.
  • Cover flashings tucked into the joints of the stack, lapping over the upturns of the lower pieces.

Lead for this work is usually milled sheet in Code 4 or Code 5, depending on the detail. Each piece is sized so that lead can expand and contract without splitting. Lead that is too long, too thin or fixed too tightly tends to crack.

Common causes of chimney leaks

Cracked or lifted flashing

Lead can split with age and thermal movement, and wind can lift poorly dressed pieces. Look for gaps between the lead and the roof, lead that has pulled out of the mortar joint, or obvious tears.

Failed pointing at the flashing line

The top edge of the flashing sits in a raked-out mortar joint and is pointed in. When that pointing cracks and falls out, water runs straight behind the lead.

Mortar fillets

On many older Irish houses, the joint between stack and roof was simply filled with sand and cement. Fillets crack as the roof and stack move independently, and they can let water in for years before the damp shows. Replacing a cracked fillet with another fillet is a short-term fix. Proper lead flashing is the long-term one.

Blocked or missing back gutter

Debris and moss collect behind the stack. If the back gutter is blocked, missing or too shallow, water builds up and overtops it. This is one reason heavy moss around a chimney is worth investigating (see moss on roof removal).

Porous stack, flaunching or no cap

Sometimes the flashing is fine and the water comes through the chimney itself. Brick and render become porous, the cement flaunching around the pots cracks, or rain falls straight down an open flue. On disused flues, a ventilated cap or cowl keeps rain out while letting the flue breathe. Some stacks also have a damp-proof tray built in, which can fail.

Condensation

Staining on a chimney breast is not always rain. Disused or poorly ventilated flues can suffer condensation and soot staining, especially when an open fire is replaced with a sealed stove or blocked up completely. A roofer or chimney specialist can usually tell the difference by checking whether the damp follows rainfall.

Diagnosing the problem

Useful clues before anyone goes up a ladder:

  • Does the damp appear during or just after heavy rain, especially wind-driven rain from one direction? That suggests a flashing or stack problem.
  • Is it on the upslope side of the stack in the attic? Check the back gutter.
  • Is it on the chimney breast lower down, without any link to rain? Think condensation.
  • Look from the ground with binoculars for lifted lead, cracked fillets or vegetation growing from the stack.

What a proper repair involves

Depending on what is found, the fix might be:

  • Re-pointing the flashing joint, if the lead itself is sound.
  • Replacing damaged sections of lead, such as a split step flashing or apron.
  • Full re-flashing, replacing the apron, steps, back gutter and covers, usually with slates or tiles around the stack lifted and relaid.
  • Replacing a mortar fillet with lead flashings.
  • Stack repairs: re-pointing, re-flaunching, fitting caps or cowls, or treating porous brickwork.

Silicone, mastic and flashing tape are sometimes used to stop a leak in a hurry, and that has its place in an emergency. They rarely last as a permanent fix because they do not allow for movement. If a temporary repair is all that is possible before winter, plan the proper job for the spring.

Safety

Chimney work is roof work: you are working at height, often on a steep slope, with heavy materials. The Health and Safety Authority expects proper access such as scaffolding or roof ladders with edge protection for this kind of job. It is not a sensible DIY task on most houses.

Related reading

Chimney leaks often go hand in hand with general roof wear. See how long a slate roof lasts for the bigger picture. Specialist leadwork is covered on the copper, lead and zinc page, and urgent leaks on the emergency repairs page. For roofers in Athlone and the Midlands, see the homepage.

Frequently asked questions

Why is my chimney leaking when it rains?

The most common causes are cracked or lifted lead flashing, failed pointing where the flashing tucks into the stack, a cracked mortar fillet, a blocked back gutter, or water coming through a porous stack or open flue.

Can chimney flashing be repaired or does it need replacing?

If the lead is sound, re-pointing the flashing joint may be enough. Split or badly fitted lead usually needs replacing, and old mortar fillets are best replaced with proper lead flashings.

Is silicone a good fix for chimney flashing?

Only as a temporary emergency measure. Sealants do not allow for movement between the stack and roof, so they tend to fail. A lasting repair uses correctly sized and fixed lead.

Could chimney damp be condensation rather than a leak?

Yes. Disused or poorly ventilated flues can cause damp and staining on the chimney breast, often unrelated to rainfall. Checking whether the damp follows rain helps tell them apart.

Related guides

This guide is general information about roofs and rainwater systems in Ireland. Grant schemes, regulations and product guidance change, so check the official source or the manufacturer's instructions before starting work.